Description
Product Description
The Freedom Won LiTE Home 40/32 HV Battery delivers robust energy storage performance for solar, hybrid, and backup power systems. Built using LiFePO₄ cell chemistry and an integrated Battery Management System (BMS), the unit offers excellent cycle life, thermal stability, and safety. It operates at a nominal 410 V DC voltage range suitable for high-voltage inverter pairings and features protections such as overcurrent, over/under-voltage, temperature monitoring, weak cell detection, and minimum state-of-charge control. A shunt-trip circuit breaker enables safe fault isolation, while the human interface with state-of-charge display, error indicator, reset button, and USB programming port enhances usability. Communication with compatible inverters and system controllers is provided via CAN Bus, which aids diagnostics and system integration. The battery comes with a 10-year warranty (or up to 6000 cycles at 80 % DoD) and an expected service life longer than a decade under recommended operating conditions.
Technical Specifications (Bullet Form)
Capacity & Energy
Total energy capacity: 40 kWh.
Usable energy at 80 % DoD: 32 kWh.
Usable energy at 90 % DoD: 36 kWh.
Electrical
Nominal voltage: 410 V DC.
Maximum operating voltage: 454 V.
Minimum operating voltage: 365 V.
Maximum continuous discharge current: 100 A.
Peak discharge current: 150 A.
Maximum continuous discharge power: 40 kW.
Peak discharge power: 61 kW.
Maximum continuous charge current: 100 A.
Short-circuit current: 5 kA.
Physical & Mechanical
Dimensions (H × W × D): 1260 × 740 × 290 mm (approx.) for the LiTE Home 40/32 HV form factor (wall/floor mount).
Weight: ~327 kg.
DC connection: 1 × 25 mm² Permopower fly leads per electrode.
Enclosure: Aluminium painted white, suitable for indoor or fully protected installations, typically IP20 rating.
Protection & Safety
Integrated BMS with cell balancing and protections for overcurrent, over/under-voltage, temperature, weak cell detection, and minimum SoC.
Shunt-trip circuit breaker for critical fault isolation.
Manual fault reset button.
Communication & Interface
CAN Bus communication for diagnostics and inverter/system controller integration.
Human interface: state of charge display (0–100 %), error indicator light, error reset button, USB programming port.
Warranty & Service Life
Standard warranty: 10 years or ~6000 cycles at 80 % DoD.
Expected service life: >13–15 years (at ~70 % DoD), 15–20 years (at ~50 % DoD).
Environmental
Designed for indoor or fully protected outdoor installation (verify specific IP rating and installation guidelines).